I have an issue on an Apple IIgs RGB monitor (A2M6014), which I recently got.

The problem is: it works well at initial power on, but after some time, the screen starts flickering and collapsing vertically, and then eventually it collapses to a horizontal band (or even to a line). The 10-second video below shows the symptom.

I found some information from the forum, although I don't have expertise at all --- I've found the schematics of the monitor, and I learned that it might be a "vertical deflection" problem, which could be caused by cold solder joints on the "HV module (flyback)". So I resoldered all the pins of the HV module (luckily I knew how to solder), but it didn't fix the problem.

What should be the next step to repair it? Any comments will be greatly appreciated!

 

 

 

 

 

 

 

Offline
Last seen: 21 hours 3 min ago
Joined: Apr 1 2020 - 16:46
Posts: 1002
The "fun" and the dangers of repairing old monitors:

Since I don't have the schematic I can't tell you much. But this is no horizontal deflection problem, it is a vertical deflection problem, and since it works - you said - after power up when the monitor is cold it's quite possible some thermal protection circuit in some IC kicks in and turns the vertical deflection off. You need to find, in the schematic, the power suppy regulator for the vertical deflection and then measure if this power supply collapses or not. If yes, seek in the power supply, if not, seek the vertical driver IC. Cold spray can also help greatly with finding the culprit. Most vertical deflection ICs with integrated output driver stage have built-in thermal self protection so if they get too hot, they turn the output stage off. A squirt of cold spray on that IC can tell you that. Also, a gentle slap with the bare hand to the monitor's enclosure might tell you if it's a intermittent contact somewhere or a hairline crack in a PCB trace which opens when the PCB gets hotter. Troubleshooting crumbling electronics is a bitch, I know. And never finger around in the monitor when it's plugged into the line voltage. The CRT also keeps a nice shocking charge (and some capacitors, too) for a long time after power is turned off. Unless you are trained and equipped to work on such dangerous things, you better let it be. There is a reason why electronics industry wide safety standards prohibit a sole person from working in the lab. There always must be at least two, so the one left after the electrical shock can hit one of the the red shutdown buttons which are everywhere.

Is it worth to get killed by an old monitor - you decide!

 

 

 

inv
Offline
Last seen: 2 years 3 months ago
Joined: Jul 21 2022 - 14:33
Posts: 4
Schematics

Thank you very much for your comments, UncleBernie. Especially about the dangers. To me learning electronics is a lot of fun, and I've been enjoying designing and building things like 8-bit computers and various microcontroller circuits. But didn't have any experience with CRT and high voltage. So, although I learned how to discharge the tube and I used working gloves with latex coating, I will keep your warning in my mind!

Attached is a schematic diagram of my monitor (Apple A2M6014). My guess is that IC401 LA7824 is used as a vertical driver (datasheet), while IC501 LA7822 is for horizontal. I guess I need to find out which parts in the schematics are closely related to vertical deflection (eg "power suppy regulator for the vertical deflection") and could be the reason of the problem. Some further comments please?

 

PDF icon[Apple] IIgs RGB monitor - Schematic diagram.pdf

inv
Offline
Last seen: 2 years 3 months ago
Joined: Jul 21 2022 - 14:33
Posts: 4
Vertical driver (LA7824) signals on a scope

I wanted to figure out which part is problematic, so I started by looking at signals of the pins of  the vertical driver LA7824 (IC401), using an oscilloscope. LA7824 datasheet shows the following pinout:

 

 

I don't understand how CRT and this IC work, but pin 7 looks like the main output signal used for "vertical deflection", so I cheked it first. When the CRT display works well, the signal was as follows. The frequency was 59.94Hz, and the min/max values were about 0.15V/-0.9V.

 

 

When the screen started flickering/collapsing, the signal reflected exactly the issue, as follows:

 

 

The following is when the screen was completely collapsed. The signal looks very bad, I guess.

 

 

I think this is exactly the problem to fix.

So I need to figure out exactly which part is bad.  The IC LA7824 itself might be bad, or some input signals to LA7824 might be bad. Thus I also investigated other signals of LA7824 (when the screen is completely collapsed.) These are as follows. Click them for larger images. Pin numbers are shown in the photos.

Among them, pin 13 is VCC (vertical), which requires 11.8V-13.2V according to the datasheet. The measured value was about 12.4V, so it looks fine.

 

 

 

Because my lack of understanding, it's pretty difficult for me to figure out exactly what causes the problem (right?) of main output signal on pin 7, and whether other signals shown above are fine. (If it is the case, the problem should be LA7824, or something connected to its pin 7, I think.)

So please let me know if anybody have any thoughts! Many thanks in advance.

 

Offline
Last seen: 21 hours 3 min ago
Joined: Apr 1 2020 - 16:46
Posts: 1002
So you got parasitic oscillations in the vertical deflection ...

... and not a thermal protection circuit kicking in.

 

Unless it's a hairline crack or some other intermittent contact, the main suspects are big electrolytic capacitors in the vertical deflection coil drive path, whose ESR may have gotten too large due to age. Alas, keeping the vertical amplifier stable and preventing oscillations is tricky business and involves a lot of parts which could have failed, too.

 

Looking at the schematic, the vertical driver stage is discrete, Q401 and Q402, and it's powered by a winding on the flyback transformer, T503, acting as a sort of switchmode power supply in this case. This is a scheme you can find quite often, the resonant power in the horizontal deflection of large CRTs is about 500W to 1kW, so it can be drained after the mains has been turned off, to power the deflection system until all the stored energy is dissipated and the beam ceases. This shuts down the system in a controlled way even if the line cord is pulled or there is a sudden blackout.  Otherwise the stored energy will find a way out, destroying components in its path. And a hole would be burned into the screen.

 

Note the J17 jumper. This would allow you to disconnect the vertical deflection system from the flyback transformer and you could power the vertical deflection system from a suitable laboratory power supply after that jumper is disconnected, so as to split the possible areas of the failed components in half. You could measure what happens on that J17 node before and during the symptom manifesting. BTW, this also is the missing link why they pointed you to the horizontal stage as being the possible culprit ... it fit does not make the supply voltage for the vertical stage, it won't work.

 

As far as I am concerned I am a lazy guy so to would just systematically apply cold spray to the components in and around the vertical driver stage while the symptom starts to manifest, and note which component reacts. Use the real, expensive, ozone layer killing, planet depopulating, terrible, banned CFC based cold spray and not the "green" one which may be flammable and make explosive vapors. But do not use more than one can to avoid killing the whole planet instantly. (Just joking, I'm only snarky about the perils these "green" idiots have brought over us, just read the instructions and warnings on your can of cold spray before you buy, if it's flammable or not). The same "green" idiots have brought the new R1234yf  refrigerant over us, good luck with that if you have a fire in the engine compartment in your car ... the fumes are extremely toxic and a hazard for bystanders and the firemen. You need a hazmat suit with autonomous respirator to safely get near that. Idiocracy. The same kind of people who poisoned kids by mandating neurotoxic flame retardants on kids bedding, kids pyjamas, and stuffed animals. And then wonder about autism and ADHD and reduced IQ in kids. All thanks to the "progressive" legislators in the People's Republic of California. Poisioning kids sure is "progress" towards a "greener" planet. But enough of that.

 

- Uncle Bernie

 

 

inv
Offline
Last seen: 2 years 3 months ago
Joined: Jul 21 2022 - 14:33
Posts: 4
I was able to find some time

I was able to find some time to investigate the problem further. Finally I figured out what was problematic --- Q401, an amplifier transitor in the vertical driver circuit. The original part was 2SC2168, but I used 2SC4883 instead, because 2SC2168 was no longer available. I made this choice by reading datasheets of transistors listed available from local online shop. I didn't have expertises and had only minimal basic understanding of how BJT and the verticial driver circuit work, so I was not sure whether it would work. Perhas luckly, 2SC4883 worked perfectly. Problem solved completely!

I appreciate comments of Uncle Bernie very much. It was very helpful for me to trance and figure out the problem. Thanks!

 

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
Macintosh 12” RGB Display (M1299 / M1296) with Similar Issue

Hello, I'm also troubleshooting a verticle foldover issue on a Macintosh 12" RGB Display.  Thanks for your comments and documents, very helpful because I've been unable to locate a schematic, however these monitors (M1299 / M1296) use the same LA7824 deflection IC, and I also see Q401 / Q402 on the board, so it could be they match up or be very close component-wise.  I found quite a few videos and articles about recapping these series of monitors, but nothing linking it to the IIGS display until I started googling on the LA7824 IC.  This is also the first content I found with oscilliscope traces, so thanks for that as well, i'm going to fire mine up and compare.  I'll post back and let you know.

 

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
Oscilliscope traces

As promised here are my scope traces.  Definitely not as pretty as inv's but here they are for comparison.  Unfortunately i'm still no closer to solving this issue.  I replaced Q401 & Q402, and now I'm tempted to recap the entire deflection board, but all the caps test out ok with my BlueESR meter.  I suspect this board has low hours on it because the big resistors on the front edge haven't had enough time to cook the capacitors as they usually do.  My next plan is to start testing the components in and around Q401 & Q402 to try and find something wrong, possibly a bad diode?  It's slow going without a schematic.

 

Pin 7

 

Pin 8

 

Pin 9

 

Pin 10

 

Pin 11

 

Pin 15

 

No Scope for Pin 13 which measured 11.86v

Online
Last seen: 51 min 4 sec ago
Joined: Jun 18 2010 - 13:54
Posts: 798
That's not a foldover problem

That's not a foldover problem. It's a Vertical Linearity issue. There should be a control for that and I'd start with adjusting it to see what it does (it might just be dirty). Otherwise, check the circuit around that function.

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
jeffmazur wrote:That's not a
jeffmazur wrote:

That's not a foldover problem. It's a Vertical Linearity issue. There should be a control for that and I'd start with adjusting it to see what it does (it might just be dirty). Otherwise, check the circuit around that function.

 

Thanks Jeff, good to know.  That would be great if it's just a dirty pot.  I tried moving all the adjustments on the board (listed below) but none of them aleviated the issue.

 

Do you have any tips on how to locate the components involved in the vertical linearity portion of the board?  I'm a CRT Newbie so learning this as I go.  I'll also google to see what I can find.  This board is similar to the PDF icon[Apple] IIgs RGB monitor - Schematic diagram.pdf  but not exact.

 

EDIT: Doing some research I see that V-LIN is the linearity pot?  I'll take a look at the components connected to it.

 

Adjustments found on the board:

 

  • H-CENT
  • V-CENT
  • V-LIN
  • H-HOLD
  • H-PHASE
  • V-HOLD
  • DRIVE-RED
  • DRIVE-BLUE
  • SUB-BRIGHT
  • SUB-CONTRAST
  • BRIGHT / FOCUS (On the side of the flyback)

 

Portion of the board I'm focusing on to right of the LA7824, again this schematic is simiar but not exact to this M1299 / M1296 12" Display

 

Online
Last seen: 51 min 4 sec ago
Joined: Jun 18 2010 - 13:54
Posts: 798
VeryVon wrote:Doing some
VeryVon wrote:
Doing some research I see that V-LIN is the linearity pot?  I'll take a look at the components connected to it.

 

 

Yes the V-LIN pot should correct this. Does anything change when you adjust it? If not (or it only makes it worse), then I'd check the pot and the resistors/capacitors connected to it.

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
jeffmazur wrote:Yes the V-LIN
jeffmazur wrote:
Yes the V-LIN pot should correct this. Does anything change when you adjust it? If not (or it only makes it worse), then I'd check the pot and the resistors/capacitors c

 

The V-LIN pot makes the image stretch & contract a bit vertically while the linerarity issue remains constant.  I replaced the capacitory in series with the pot, no improvement.  Resistors seem fine, I'll keep testing.

Online
Last seen: 51 min 4 sec ago
Joined: Jun 18 2010 - 13:54
Posts: 798
That sounds more like the

That sounds more like the HEIGHT pot. If the VLIN pot does the same, then I'd suspect C404 shown in the IIgs schematic that you linked to:

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
Caps In Question

Ok.  I'm attempting to locate the circuitry & caps that would be equivalent to those.  One issue I'm having is they're not all electrolytic, so I can't test them with my ESR meter.  Here's the area in question:

CVT
CVT's picture
Offline
Last seen: 8 hours 46 min ago
Joined: Aug 9 2022 - 00:48
Posts: 1174
The brown ones in your yellow

The brown ones in your yellow circle are tantalum capacitors and they are probably fine. Be careful when you put them back not to reverse their polarity, because they will explode quite violently. Also why do you even bother testing electrolytic capacitors, when you can simply replace them? Capacitors are super cheap and it takes longer to remove, test and put back than to remove and put brand new ones.

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
CVT wrote:The brown ones in
CVT wrote:

The brown ones in your yellow circle are tantalum capacitors and they are probably fine. Be careful when you put them back not to reverse their polarity, because they will explode quite violently. Also why do you even bother testing electrolytic capacitors, when you can simply replace them? Capacitors are super cheap and it takes longer to remove, test and put back than to remove

 

Thanks for the tips, yes I've seen the tantalum's blow before on old motherboards, quite a spark! 

Agree, caps are quite cheap and easy to replace.  I've tested all the electrolytic capacitors in-circuit using a BlueESR tester and they come up clean.  I'd like to try and track down the specific problem before replacing everything if possible.

CVT
CVT's picture
Offline
Last seen: 8 hours 46 min ago
Joined: Aug 9 2022 - 00:48
Posts: 1174
BlueESR is a wonderful tool

BlueESR is a wonderful tool that lets you find bad capacitors fast, but it is not an if-and-only-if situation. In other words it can give you a sure fail, but it cannot give you a sure pass. For example old electrolytic capacitors sometimes become leaky at their in-circuit operating voltage, which can be quite high in a CRT monitor. This is something you cannot possibly detect with an in-circuit ESR meter, since its testing voltage is quite low. To test them properly you need to take them out of circuit and set up a wave generator at their operating voltage – way too complicated as opposed to just changing them with brand new ones.

 

The other issue I see here is that you are trying to find a problem without having the schematics. Using schematics of a different model is no good. If you want to go this way, you should start by putting at least part of the schematics down on paper, which is not hard with a single layer board. Some experienced TV/CRT monitor repair people can even look at a high resolution picture of the top and bottom of the main board and give you some valuable advice, so at least post those.

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
CVT wrote:BlueESR is a
CVT wrote:

BlueESR is a wonderful tool that lets you find bad capacitors fast, but it is not an if-and-only-if situation. In other words it can give you a sure fail, but it cannot give you a sure pass. For example old electrolytic capacitors sometimes become leaky at their in-circuit operating voltage, which can be quite high in a CRT

Wow, good to know, I hadn't considered "in-circuit operating voltage," thanks for the tip!

Agree about starting to work out the schematic on paper, I'll start that process.  Also the images.  Here's the (full) bottom split into two images, I'll get a picture of the top and post that later:

CVT
CVT's picture
Offline
Last seen: 8 hours 46 min ago
Joined: Aug 9 2022 - 00:48
Posts: 1174
Take a look at this video -

BTW, take a look at this video - same monitor as yours and similar problem to yours. I didn't find a later repair video in his channel, but in the comments 3 years later he mentions that it was caused by leaky capacitors:

 

https://www.youtube.com/watch?v=MarjYE1xse4

 

Here is another example of the same problem as in the video above, also fixed by a recap:

 

https://pappp.net/?p=26231

 

 

Offline
Last seen: 5 days 11 min ago
Joined: Apr 26 2016 - 08:36
Posts: 745
CVT wrote:Here is another
CVT wrote:

Here is another example of the same problem as in the video above, also fixed by a recap:

 

https://pappp.net/?p=26231

 

Let's be clear here.  The procedure in the above video was not a "recap".  It was a repair that involved changing one failed part, which happened to be a capacitor.  That capacitor was very likely under spec-ed to begin with.  (Good electronics designers don't use 6.3V caps in 5V circuits.  Those decisions are usually made by bean counters who want to save 3 cents on that part.)

CVT
CVT's picture
Offline
Last seen: 8 hours 46 min ago
Joined: Aug 9 2022 - 00:48
Posts: 1174
...The procedure in the above

...

The procedure in the above video was not a "recap".  It was a repair that involved changing one failed part, which happened to be a capacitor.

...

 

It was precisely a recap, just not a full recap. You always start with the one capacitor you suspect the most and move on down. Once you fix the problem, it's up to you if you want to change the rest or stop there.

Offline
Last seen: 8 months 1 week ago
Joined: Aug 12 2022 - 08:21
Posts: 19
Repair Videos & Articles

Thanks for the links guys!  I will study those.

Log in or register to post comments